NobelActive® Implant Fixture
NOBEL BIOCARE / Switzerland / Sweden / Premium Surgical

NobelActive®

Expanding Tapered Core & Reverse-Buttress Bone Condensation for Demanding Cases

Alloy: Commercially Pure Cold-Worked Titanium Grade 4 (CP4) with 800–900 MPa tensile strength.
Surface: TiUltra™ multi-zone anodized hydrophilic surface (golden smooth collar to Sa 1.5 µm porous body).
Connection: Internal Conical Connection (12° Morse taper) with internal hexagonal interlocking seal.
Global Market Tier:
Premium Surgical
Medically reviewed by Verified Specialist
Last verified: November 18, 2026
Dr. RASHA OWDA
✓
Dr. RASHA OWDA (Asst. Prof. BDS, PhD • Implantology & Aesthetic Dentistry)

Implantology, Aesthetic & Restorative Dentistry

TDB Medical License: TR-IST-62819 18+ Years Experience Turkey (Turkish Ministry of Health)

Dr. Rasha Owda (PhD, Istanbul University; former Assistant Professor at Biruni & Istanbul Aydin Universities) is an Implantology, Aesthetic & Restorative Dentistry expert with 18 years of clinical experience and founder of an international dental academy at Gleam Clinic.

Clinical review conducted under International Team for Implantology (ITI) guidelines and USHAŞ standards.
100% Editorial Independence
Clinical Assessment & Surgical Considerations

Clinical Assessment & Surgical Considerations: NobelActive®

NobelActive® stands as the global pioneer of surgical osseocondensation and immediate implant placement. Engineered with an aggressively expanding tapered core and progressive double-lead reverse-buttress threads, the fixture functions like an internal bone-condensing osteotome during insertion. Rather than stripping soft trabecular bone, the angled threads compress spongy trabeculae radially, routinely delivering 35–70 Ncm insertion torque in compromised maxillary bone where parallel-walled implants frequently fail to stabilize.

Its signature anatomical feature is the dual sharp self-drilling apical cutting blade assembly. This permits an experienced oral surgeon to actively redirect the implant's longitudinal axis mid-insertion—a lifesaving surgical feature when aligning a prosthetic emergence trajectory within fresh anterior extraction sockets. However, this aggressive apex requires disciplined anatomical verification near the sinus floor or inferior alveolar canal.

Now upgraded with the anodized TiUltra™ gradient surface and warm golden collar hue, NobelActive merges high primary mechanical lock with clean biological soft-tissue adaptation around a 12-degree internal conical seal, preventing grayish show-through beneath thin anterior labial gingiva.

Biomechanical & Clinical Engineering Specifications — NobelActive®

Comprehensive 12-point surgical & biomechanical architecture with technical cross-section visuals

01

Macro-Design & Thread Architecture

Expanding tapered core, reverse-buttress double-lead threads, self-drilling apical blades, back-taper collar.

  • Core & Threads: Expanding tapered body with deep, progressive reverse-buttress double-lead threads designed to pull bone inward and compress trabeculae.
  • Active Apical Blades: Two sharp spiral apical cutting blades permit active trajectory redirection during immediate socket engagement.
  • Back-Tapered Crestal Collar: Reverse back-taper coronal neck maximizes crestal alveolar bone volume and built-in platform shifting.
Macro-Design & Thread Architecture
Active reverse-buttress thread geometry compressing soft trabeculae for primary lock.
02

Implant-Abutment Connection

Internal Conical Connection (12° Morse taper) with internal hexagonal interlocking seal.

  • Conical Architecture: 12° Morse taper conical seal paired with a tactile 6-sided interlocking hexagon preventing micro-rotation and screw loosening.
  • Platform Compatibility: Color-coded platforms (3.0, NP, RP, WP) share identical restorative libraries across NobelParallel CC and NobelReplace CC.
Implant-Abutment Connection
12° Internal Conical Connection isolating biological micro-leakage.
03

Biomaterial & Metallurgy

Commercially Pure Cold-Worked Titanium Grade 4 (CP4) with 800–900 MPa tensile strength.

  • Cold-Worked CP4 Metallurgy: Pure biocompatible Titanium Grade 4 strengthened via cold-working to achieve ~800–900 MPa tensile strength without alloying.
04

Surface Treatment & Hydrophilicity

TiUltra™ multi-zone anodized hydrophilic surface (golden smooth collar to Sa 1.5 µm porous body).

  • Zoned Anodization: Graduated non-porous golden anodized collar prevents bacterial plaque adherence and tissue greying; lower body features porous TiO2.
Surface Treatment & Hydrophilicity
Multi-zone anodized TiUltra topography optimizing mucointegration and bone growth.
05

Dimensional Range & Anatomy

Diameters: 3.0 (Narrow), 3.5 (NP), 4.3 (RP), 5.0 (RP), 5.5 (WP) mm. Lengths: 8.5 to 18 mm.

  • 3.0 mm Dedicated Lateral: Special ultra-narrow 3.0 mm fixture expressly cleared for tight anterior maxillary lateral and mandibular incisors.
06

Clinical Performance & Torque

Target torque 35–45 Ncm (up to 70 Ncm max); ISQ > 72; benchmark for immediate sockets.

  • Immediate Temporization: Excels at achieving immediate crown stability in low-density posterior maxilla and fresh anterior extraction sockets.
07

Surgical Kit & Guided Workflow

Stepped drills with dense bone drills + DTX Studio™ / NobelGuide® full-arch templates.

  • Protocol Nuance: Under-sizing is adjusted selectively based on tactile bone quality D1 vs D4; includes dense bone screw taps for hard cortical crests.
Surgical Kit & Guided Workflow
NobelGuide™ precision surgical template integration with depth-calibrated drills.
08

Prosthetic Ecosystem & Digital CAD/CAM

All-on-4® Multi-Unit Abutments (MUA), On1™ concept, Universal Base, NobelProcera® CAD/CAM.

  • All-on-4® Pioneer: The proprietary inventor ecosystem for full-arch tilted Multi-Unit Abutments (17° and 30°), Angulated Screw Channels (ASC), and On1™ tissue collar.
09

Scientific Evidence & Literature

97.2%–99.1% long-term survival rate; 4,000+ studies rooted in Brånemark osseointegration legacy.

  • Multi-Center Proof: Extensive 10-year clinical follow-ups validating survival in immediate loading and complex maxillary sinus protocols.
10

Certifications & Regulatory Compliance

CE MDR Class IIb, US FDA 510(k), Turkey MoH ÜTS registered with Patient Authenticity Card.

  • Regulatory Footprint: Full MDR, FDA, Health Canada, and ÜTS registration with sterile gamma packaging and serialized batch passports.
11

Packaging & Surgical Ergonomics

Mount-free internal driver pickup in sterile dual-peel blister; color-coded platforms.

  • Surgical Speed: Color-coded magenta (NP), yellow (RP), and blue (WP) indicators eliminate prosthetic mismatching during surgery.
12

Warranty & Global Supply Chain

Nobel Biocare Lifetime Warranty on fixtures and titanium prosthetics; global 80+ country network.

  • Warranty Support: Free implant replacement warranty globally with seamless compatibility across international clinics.